Brand Name: | ZGD |
Model Number: | ZGD-M60 |
Place of Origin: | Guangdong, China |
MOQ: | 1 |
Price: | $500.00/Pieces 1-9 Pieces |
Payment Terms: | T/T, Western Union |
Supply Ability: | 10000 Piece/Pieces per Month |
Delivery Time: | 10-15 work days |
Packaging Details: | wooden box |
Certification: | CE |
Phase: | Three Phase |
Protection: | Short Circuit |
Weight: | 295kg |
Type: | On-line |
Product name: | Low Frequency Online UPS |
Capacity: | 60KVA |
Battery Type: | Lead Acid Battery |
Wave Form: | Pure Sine Wave |
Input voltage: | 305VAC - 460VAC |
Output: | 380VAC 3+N+PE 50HZ |
Modular Protection 60kva Low Frequency Online UPS Power Supply
Modular UPS Overcurrent Protection Uninterruptible Power Supply With Module 60kva
Features
1.With emergency shutdown (EPO) switch and remote emergency
shutdown (REPO) function;
2.Perfect software and hardware protection functions (C-level
lightning protection, air-opening, Fuse, hardware protection,
software protection), super self-diagnosis function, rich history
query;
3.Large LCD touch widescreen display for a friendly human-machine
interface;
4.Rich communication interface, including RS232, RS485, USB, Dry
contact, and SNMP (optional) card;
5.Different external batteries can be selected according to user
needs (32/34/36/38/40 pcs);
6.Support battery cold start and city power self-start function to
meet user needs With maintenance bypass, when there is an
emergency, you can switch to the maintenance bypass power supply,
and the maintenance personnel can safely perform online
maintenance;
7.Each module adopts an independent control system. And the UPS
module is independently controlled according to the shared
information. After the faulty module fails, it can be disconnected
from the parallel system immediately, which does not cause harm to
the parallel system.
Application Area:
Post and telecommunications, electric power, communication and
other industries, enterprises and institutions network room and
data center.
Model | ZGD-M80 | |||||
Phase | 3-phase in / 3-phase out | |||||
Capacity | 80KW or 120KW | |||||
One power module capacity | 20KVA/20KW | |||||
Battery type | External battery | |||||
MAX.power module NO. | 4 | |||||
INPUT | ||||||
Nominal Voltage | 3x380VAC/400VAC/415VAC(3Ph+N) | |||||
Voltage range | 305-478VAC at 100%load; 208-304VAC at<70% load | |||||
Frequency range | 40-70Hz | |||||
Power factor | >0.99 @100% load, > 0.98 @ 50%load | |||||
Harmonic distortion | <3% @ 100% load | |||||
OUTPUT | ||||||
Nominal Voltage | 3x380VAC/400VAC/415VAC(3Ph+N) | |||||
Voltage regulation | ≤±1% typical (balanceload), ≤±2% typical (unbalanceload) | |||||
Nominal range | 50/60Hz | |||||
Frequency range | 46- 54Hz or 56 - 64Hz | |||||
THDu | THD<1%( linear load),THD<5.5%(non- linear load) | |||||
Overload Capacity | 1 hour for 110%,10 mins for 125%,1min for 150%,200ms for >150% | |||||
Total Harmonic Distortion | ≤2% (linear load); ≤4% (non-linear load) | |||||
Efficiency | Up to 94.5% | |||||
BATTERY / CHARGER | ||||||
Nominal Voltage | ±216VDC(12V x 36pcs) | |||||
Max.Voltage | ±240VDC(12V x 40pcs) | |||||
Min. Voltage | ±192VDC(12V x 32pcs) | |||||
Floating current voltage | 2.25V /Cell | |||||
Boost current voltage | 2.35V / Cell | |||||
Temperature compensation | yes | |||||
Max.charging current | 8A | 8A for 30kw power module | 6A | 8A | ||
Per power module | 6A for 20kw power module | |||||
PHYSICAL | ||||||
Cabinet dimension(mm) | 1100x600x1475 | 1100x600x2010 | 1100x600x1475 | 1100x600x1475 | 1100x600x2010 | |
Net weight(KGS) | 675 | 932 | 335 or 333 | 437.5 or 434.5 | 611 | 549 |