20KA Alternating Withdrawable VCB Circuit Breaker 12KV

Categories VCB Circuit Breaker
Brand Name: KNKONG
Model Number: VS1-12
Certification: CB,ISO,IEC
Place of Origin: China
MOQ: 1
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000 Unit per month
Delivery Time: 15 working days
Packaging Details: Standard export packaging
Voltage: 12KV
Current: 630A 1250A
Breaking current: 20KA
Type: withdrawable
Original: China
Manufactory: KNKONG
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

20KA Alternating Withdrawable VCB Circuit Breaker 12KV

VS1 Series Vacuum Circuit Breaker 12KV 630-1250A

Voltage: 12KV

Current: 630-1250A

Breaking current: 20KA

Type: withdrawable


Product overview

VS1-Series embedded pole. vacuum circuit breakers are applicable to 12kV, three-phase AC 50Hz indoor switchgear and can serve as protection and control units for industrial and mining establishment transformer substation equipment. With modular and independent-frame design for their spring operating mechanisms, VS1-Series circuit breakers can operate with KYN28-12(24) mid-set and fixed switchgear. These circuit breakers are subject to both fixed installation and assembly with the truck as a handcart unit


Applicable standards

1EC62271-100 High-voltage switchgear and control-gear-Part 100: Alternating-current circuit-breakers


Secondary circuit

VS1-Series vacuum circuit breakers adopt modular designs for their secondary control circuit boards. The electric connection of the mechanisms employs high-grade self-fastener plugs, which both facilitates replacement and ensures reliable electrical connection


High-performance oil buffer

High-performance breaking buffer can markedly reduce the overshoot and rebounding amplitudes of the moving contact of a vacuum circuit breaker in breaking thus avoiding the loss of mechanical endurance due to partial over fatigue of vacuum interrupter bellows resulting from moving contact overshoot. As the rebounding amplitudes of the moving contact reduces, No re-ignition and restrike is found during the switching capacitor bank test


Technical Parameters

No.ItemUnitParameter
1Rated voltageKV12
2Rated frequencyHz50/60
3

Rated insulation level

1min power frequency withstand voltage(r. m. s)

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)


4


Rated current


A

63063012501600
1250125016002000
20002500
25003150
4000
5Rated short-circuit breaking current

KA

202531.540
6Rated short-time withstand current202531.540
7Rated short-circuit marking current506380100
8Rated peak withstand current506380100
9Rated duration of short-circuits4
10Rated operating sequenceO-0.3s-O/C-180s-O/C
11Breaking times of rated short-circuit currentTimes30/20 times(40KA)
12Mechanical enduranceOps20000
13Rated single capacitor bank breaking current

A

630
14Rated back-to-back capacitor bank breaking current400
15Double-earth fault breaking current27.4
16Allowable maximum contact erosion

mm

3
17Clearance between open contacts10±1
18Over stroke3.5±0.5
19Non-simultaneity of 3-phase opening and closing

ms


≤2
20Bounce duration of contact closing≤2
21Average breaking speed (instant breaking 6mm)

m/s


1.1±0.2
22Average making speed0.8±0.2
23Making time

ms


≤100
24Breaking time≤50

25


Resistance of each phase main circuit


μ Ω

630A≤50
1250A≤45
1600A~2000A≤35
≥2500A≤25
26Contact breaking bounce amplitudemm≤2

27

Rated operating voltageRated operating voltage(V)AC/DC

V

24*110220
Scope of normal operation voltageOpening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28Rated voltage of energy storage motorVAC110/220,DC110/220
29Energy storage timeS≤15

Operation safety

With anti-maloperation locking protection these circuit breakers, working in switchgear cabinets, can realize "five-protection" interlocking functions, avoiding malapert and maximizing the protection of an operator's personal safety.

Only when the circuit breaker and earthing switch are in the disconnected position can the truck of circuit breaker be racked to the service position from the test position

The circuit breaker can be closed only when in the service/test position.

With the circuit breaker closed its truck cannot be racked in or racked out which can be realized only when the circuit breaker is in the disconnected position.

The circuit breaker in a closed position cannot be racked out from the service position to the test position.

The circuit breaker cannot be closed while it is being racked in.

When the circuit breaker is closed, if the closing signal fails to be removed timely, the internal anti-trip control circuit will cut off the closing circuit to prevent multiple reclosing (optional).

If the electric closing lockout is selected, the circuit breaker will be unable to be closed when the secondary circuit fails to provide power or the power provided fails to meet the normal operation of the locking electromagnet(optional).


Quality 20KA Alternating Withdrawable VCB Circuit Breaker 12KV for sale