Brand Name: Lanry
Model Number: TF1100-EI
Certification: CE
Place of Origin: Shanghai, China (Mainland)
MOQ: 1 Unit
Price: Negotiable
Supply Ability: 100unit/week
Packaging Details: Carton Packing
Response time: 0.5s
Communication: 4~20mA, OCT
Sensitivity: 0.003m/s
Transducer range: DN20-DN6000
Application: oil,liquid,For Water
Protection level: IP65
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Data Logger Insertion Ultrasonic Flow Meter

Long-term stability Insertion Transit Time Ultrasonic Flow Meter with data logger

Intrusive Transit time ultrasonic flow meter TF1100-EI is suitable for system integrators supporting projects, water resources or heating systems and network monitoring projects flow measurement, with a small size, low price, simple operation, complete output interface features.
Intrusive Transit time ultrasonic flow meter TF1100-EIprovides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
Long-term stability Insertion Transit Time Ultrasonic Flow Meter with data loggerFeatures:
1. Spool-piece transducer for best accuracy and beter long-term stability.
2. No moving parts, no pressure drop, no maintenance.
3. The heat measurement function by configuring with paired temperature sensors.
4. High temp. Insertion tansducers are suitable for high temperature of -35℃~150℃.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s.


Application

General

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

● Energy efficiency audits

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

Specifications:Transmitter


Measurement principleUltrasonic transit-time difference correlation principle
Flow velocity range0.01 to 12 m/s, bi-directional
Repeatability0.2% of reading
Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time0.5s
Sensitivity0.003m/s
Resolution0.25mm/s
Damping of displayed value0-99s(selectable by user)
Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
Power SupplyAC: 85-265V DC: 24V/500mA
Enclosure typeWall-mounted
Degree of protectionIP66 according to EN60529
Operating temperature-20℃ to +60℃
Housing materialFiberglass
Display4 line×16 English letters LCD graphic display, backlit
UnitsUser Configured (English and Metric)
RateRate and Velocity Display
Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
Thermal energyunit GJ,KWh can be optional
Communication4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
SecurityKeypad lockout, system lockout

Specifications:Transducer


Degree of protectionIP67 or IP68 according to EN60529
Suited Liquid TemperatureStd. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Transducer SizeType S Φ58*199mm
Material of transducerStainless Steel
Pipe diameter rangeDN65-6000
Cable LengthStd: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%



Packing & Delivery


Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application


With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.

Delivery

Inserted Type Ultrasonic Flow Meter With 4-20mA Output

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Quality Data Logger Insertion Ultrasonic Flow Meter for sale
Send your message to this supplier
 
*From:
*To: Lanry Instruments (Shanghai) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0