Sign In | Join Free | My hardware-wholesale.com
hardware-wholesale.com
Products
Search by Category
Home > Industrial Controls >

CISPR16-1-4 Tricyclic Radiation Magnetic Field Induced Current Test System for Luminaries

Categories EMC Test Equipment
Brand Name: Sinuo
Model Number: SN667
Certification: Calibration Certificate (Cost Additional)
Place of Origin: China
MOQ: 1
Price: Customized
Payment Terms: L/C, , T/T, Western Union, MoneyGram
Supply Ability: 1 set per month
Delivery Time: 60 Days
Packaging Details: Plywood
Test Samples: Lighting equipment
Test Environmen: Shielded room
Power Supply: 380V ± 10%, 50 / 60Hz
Applied Standard: CISPR15 & CISPR16-1-4
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

CISPR16-1-4 Tricyclic Radiation Magnetic Field Induced Current Test System for Luminaries

CISPR16-1-4 Tricyclic Radiation Magnetic Field Induced Current Test System for Luminaries


Standards & Clauses:


CISPR15/ GB17743: Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

CISPR16-1-4: Radio disturbance and immunity measuring apparatus –Ancillary equipment –Radiated disturbances Reference


Samples and Restrictions:


Luminaries and other devices


Application:


For lighting and other devices that may produce low-frequency magnetic field, the loop antenna system required by the CISPR16-1-4 standard shall be used to measure the low-frequency magnetic field radiation harassment.


Test Principle:


The measured object (EUT) is placed in the middle of the three-loop antenna. The three-loop antenna converts the low frequency magnetic field components in the X direction, the Y direction and the Z direction into an RF signal and switches the three channels through the coaxial switch to the EMI receiver measuring. The test should be conducted in a shielded room.


Structure:


Main test equipment: receivers, three-loop antenna, EMC test software
Test environment: shielded room (height greater than 3.3m)


Use Environment​:


Power supply: 380V ± 10%, 50 / 60Hz
Ambient temperature: 5 °C ~ +40 °C, there should be no high concentration of dust, corrosive gas, flammable and explosive objects


Technical Parameters:


Main Test EquipmentReceivers, three-loop antenna, power absorbing clamp, decoupling clamp, slide rail, EMC test software, etc.
Test EnvironmentShielded room (height greater than 3.3m)
Schematic Diagram
Quality CISPR16-1-4 Tricyclic Radiation Magnetic Field Induced Current Test System for Luminaries for sale
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0