| Sign In | Join Free | My hardware-wholesale.com |
|
| Categories | High Temperature Centrifugal Fan |
|---|---|
| Brand Name: | XIANRUN BLOWER |
| Model Number: | ZR-HT SERIES |
| Certification: | CE, ISO 9001 |
| Place of Origin: | XINXIANG |
| MOQ: | 1 |
| Price: | 50-50000 |
| Payment Terms: | L/C, D/A, D/P, T/T |
| Supply Ability: | 10000 |
| Delivery Time: | 5-45DAYS |
| Packaging Details: | WOODEN PACKING |
| Voltage: | 220V/380V/440V/480V/660V |
| Blade material: | Stainless Steel,Cast Iron,Steel plate,Q345 (16Mn) manganese steel |
| Air volume: | 800 - 90000m3/h |
| Power: | 5 - 350KW |
| Warranty: | 1 Year |
| Color: | Customer's Requirement |
| Material: | Steel,316L,Carbon Steel /Stainless Steel,Q235 |
| Applications: | Cooling systems |
| Name: | Industrial Axial Flow Fan |
| Company Info. |
| Henan Xianrun Blower CO.,LTD |
| Verified Supplier |
| View Contact Details |
| Product List |
The stainless steel centrifugal fan produced by professional
stainless steel centrifugal fan manufacturers has high temperature
resistance characteristics, such as higher temperature requirements
can also be professionally customized through technical means. The
motor phase lack of stainless steel centrifugal fan is the killer
of three-phase asynchronous motor. The three-phase load is
symmetrical when the motor is running normally, so the three-phase
current is basically balanced and the size is equal.
If the motor is out of phase in operation (the phenomenon that any
phase in the three-phase winding is disconnected is called out of
phase), the vibration of the stainless steel centrifugal fan will
become larger, there will be abnormal sound, the speed will
decrease, the current will increase, and the motor temperature will
rise rapidly, which will cause the motor to burn out. The motor
with general quality will burn out in ten minutes.
What is terrible is the lack of phase of the entire power supply
system, coupled with the switch of many equipment is self-locked or
automatically opened, and then the lack of phase accident after a
power outage may burn more than a dozen motors.
The motor cannot start when the power is out of phase, and the motor in operation can still run after the phase is out of phase, but the magnetic field is distorted, and the harmful current component is accelerated, leading to the burning of the winding.